drugset / Trial / NCT00543400
Evaluation of M118 in Percutaneous Coronary Intervention (EMINENCE)
RandomizedParallel-groupOpen-labelPrevention
Summary
The primary objective is to evaluate the safety and feasibility of using M118 as an anticoagulant in the target population of subjects with stable coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). The secondary objectives are to evaluate the effect of M118 on procedural indices including procedure success, abrupt closure, post-procedure TIMI flow, and catheter thrombus. Substudy Primary Objective The primary objective of the substudy is to characterize the pharmacokinetic and pharmacodynamic profile of M118 among subjects with stable coronary artery disease undergoing elective PCI.
Timeline
- Start
- 2007-09
- Primary completion
- 2009-04
- Completion
- 2009-05
Publications
- Background Melloni C, Fier I, Roach J, Kosinski AS, Broderick S, Sigmon K, Myles S, Becker RC, Rao SV; EMINENCE Investigators. Design and rationale of the Evaluation of M118 IN pErcutaNeous Coronary intErvention (EMINENCE) trial. Am Heart J. 2009 Nov;158(5):726-33. doi: 10.1016/j.ahj.2009.08.020. Epub 2009 Sep 30.
- Results Rao SV, Melloni C, Myles-Dimauro S, Broderick S, Kosinski AS, Kleiman NS, Dzavik V, Tanguay JF, Chandna H, Gammon R, Rivera E, Alexander JH, Fier I, Roach J, Becker RC; EMINENCE Investigators. Evaluation of a new heparin agent in percutaneous coronary intervention: results of the phase 2 evaluation of M118 IN pErcutaNeous Coronary intErvention (EMINENCE) Trial. Circulation. 2010 Apr 20;121(15):1713-21. doi: 10.1161/CIRCULATIONAHA.109.913277. Epub 2010 Apr 5.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Comparator | Heparin | Other / unclassified | 70 iu/kg | Intravenous |
| Subject | M118 | Other / unclassified | 50 iu/kg | Intravenous |
| Subject | M118 | Other / unclassified | 75 iu/kg | Intravenous |
| Subject | M118 | Other / unclassified | 100 iu/kg | Intravenous |