drugset / Trial / NCT00886444

Comparative Evaluation of Various Combinable Magnetic Resonance (CMR) Pulse-sequences for Macrophage Imaging Using Ferucarbotran

NCT00886444 ↗

NaSingle-groupOpen-labelDiagnostic

Summary

The aim of this study is to: * clarify whether macrophage imaging using ferucarbotran is able to delineate the region of myocardial infarction as accurate as gadolinium-based necrosis/fibrosis imaging; * identify possible differences in infarct imaging using ferucarbotran for macrophage imaging compared to necrosis/fibrosis imaging with gadolinium-based compounds; and * evaluate which MRI pulse-sequences maximise sensitivity for macrophage imaging with ferucarbotran in the setting of acute myocardial infarction.

Timeline

Start
2009-03
Primary completion
2010-03
Completion
—

Drugs

EvaluationDrugModalityDoseRoute
Subject Ferucarbotran Diagnostic / imaging agent — Intravenous