drugset / Trial / NCT01841307

Cromolyn Detection of Silent Aspiration

NCT01841307

NaSingle-groupOpen-labelDiagnostic

Summary

The overall purpose of this project is to develop and validate a simple, non-invasive method to detect aspiration of gastro-intestinal fluid into the respiratory tract. In the inpatient setting, the investigators will compare the quantity of cromolyn detected in urine collected overnight after 4 ingestions (at 2h intervals) of a 200 mL of a 1mg/mL solution of cromolyn sodium, by 5 healthy control subjects and 5 patients (3-6 with pulmonary fibrosis; and 3-6 either awaiting or recently undergone lung transplantation) with clinical and laboratory evidence of GER (gastroesophageal reflux) with microaspiration. In the outpatient setting, the investigators will compare the quantity of cromolyn detected in urine collected overnight after 1 ingestions (at 4h intervals) of a 200 mL of a 1mg/mL solution of cromolyn sodium, by 10 patients (3-6 with pulmonary fibrosis; and 3-6 either awaiting or recently undergone lung transplantation) with clinical and laboratory evidence of GER (gastroesophageal reflux) with microaspiration.

Timeline

Start
2015-07
Primary completion
2017-03
Completion
2017-09

Drugs

EvaluationDrugModalityDoseRoute
Subject Cromolyn Small molecule 200 mg Oral