drugset / Trial / NCT01973504
Phase 2c Dose Comparison Study of MP4OX in Trauma
RandomizedParallel-groupQuadruple-blindTreatment
Summary
MP4OX is being developed as an ischemic rescue therapy to perfuse and oxygenate tissues at risk during hemorrhagic shock. MP4OX is a pegylated hemoglobin-based colloid designed to improve perfusion and target delivery of oxygen to ischemic tissues. This study will evaluate safety and efficacy of MP4OX treatment, in addition to standard therapy, in trauma patients suffering from lactic acidosis due to severe hemorrhagic shock.
Timeline
- Start
- 2013-12
- Primary completion
- 2015-12
- Completion
- 2016-03
Outcome
Outcome not reported
Stopped: “Sangart ceased operations”
Publications
- Background Cole RH, Vandegriff KD. MP4, a vasodilatory PEGylated hemoglobin. Adv Exp Med Biol. 2011;701:85-90. doi: 10.1007/978-1-4419-7756-4_12.
- Background Young MA, Lohman J, Malavalli A, Vandegriff KD, Winslow RM. Hemospan improves outcome in a model of perioperative hemodilution and blood loss in the rat: comparison with hydroxyethyl starch. J Cardiothorac Vasc Anesth. 2009 Jun;23(3):339-47. doi: 10.1053/j.jvca.2008.08.006. Epub 2008 Oct 22.
- Background Vandegriff KD, Winslow RM. Hemospan: design principles for a new class of oxygen therapeutic. Artif Organs. 2009 Feb;33(2):133-8. doi: 10.1111/j.1525-1594.2008.00697.x.
- Background Vandegriff KD, Malavalli A, Mkrtchyan GM, Spann SN, Baker DA, Winslow RM. Sites of modification of hemospan, a poly(ethylene glycol)-modified human hemoglobin for use as an oxygen therapeutic. Bioconjug Chem. 2008 Nov 19;19(11):2163-70. doi: 10.1021/bc8002666.
- Background Svergun DI, Ekstrom F, Vandegriff KD, Malavalli A, Baker DA, Nilsson C, Winslow RM. Solution structure of poly(ethylene) glycol-conjugated hemoglobin revealed by small-angle X-ray scattering: implications for a new oxygen therapeutic. Biophys J. 2008 Jan 1;94(1):173-81. doi: 10.1529/biophysj.107.114314. Epub 2007 Sep 7.
- Background Cole RH, Vandegriff KD, Szeri AJ, Savas O, Baker DA, Winslow RM. A quantitative framework for the design of acellular hemoglobins as blood substitutes: implications of dynamic flow conditions. Biophys Chem. 2007 Jun;128(1):63-74. doi: 10.1016/j.bpc.2007.03.004. Epub 2007 Mar 13.
- Background Young MA, Riddez L, Kjellstrom BT, Bursell J, Winslow F, Lohman J, Winslow RM. MalPEG-hemoglobin (MP4) improves hemodynamics, acid-base status, and survival after uncontrolled hemorrhage in anesthetized swine. Crit Care Med. 2005 Aug;33(8):1794-804. doi: 10.1097/01.ccm.0000172648.55309.13.
- Background Drobin D, Kjellstrom BT, Malm E, Malavalli A, Lohman J, Vandegriff KD, Young MA, Winslow RM. Hemodynamic response and oxygen transport in pigs resuscitated with maleimide-polyethylene glycol-modified hemoglobin (MP4). J Appl Physiol (1985). 2004 May;96(5):1843-53. doi: 10.1152/japplphysiol.00530.2003. Epub 2004 Jan 16.
- Background Winslow RM, Lohman J, Malavalli A, Vandegriff KD. Comparison of PEG-modified albumin and hemoglobin in extreme hemodilution in the rat. J Appl Physiol (1985). 2004 Oct;97(4):1527-34. doi: 10.1152/japplphysiol.00404.2004. Epub 2004 Jun 18.
- Background Vandegriff KD, Bellelli A, Samaja M, Malavalli A, Brunori M, Winslow RM. Kinetics of NO and O2 binding to a maleimide poly(ethylene glycol)-conjugated human haemoglobin. Biochem J. 2004 Aug 15;382(Pt 1):183-9. doi: 10.1042/BJ20040156.
- Background Tsai AG, Vandegriff KD, Intaglietta M, Winslow RM. Targeted O2 delivery by low-P50 hemoglobin: a new basis for O2 therapeutics. Am J Physiol Heart Circ Physiol. 2003 Oct;285(4):H1411-9. doi: 10.1152/ajpheart.00307.2003. Epub 2003 Jun 12.
- Background Vandegriff KD, Malavalli A, Wooldridge J, Lohman J, Winslow RM. MP4, a new nonvasoactive PEG-Hb conjugate. Transfusion. 2003 Apr;43(4):509-16. doi: 10.1046/j.1537-2995.2003.00341.x.
- Background McCarthy MR, Vandegriff KD, Winslow RM. The role of facilitated diffusion in oxygen transport by cell-free hemoglobins: implications for the design of hemoglobin-based oxygen carriers. Biophys Chem. 2001 Aug 30;92(1-2):103-17. doi: 10.1016/s0301-4622(01)00194-6.
- Background Young MA, Riddez L, Kjellstrom BT, Winslow RM. Effect of maleimide-polyethylene glycol hemoglobin (MP4) on hemodynamics and acid-base status after uncontrolled hemorrhage in anesthetized swine: comparison with crystalloid and blood. J Trauma. 2007 Dec;63(6):1234-44. doi: 10.1097/TA.0b013e31815bd7b0.
- Background Wettstein R, Tsai AG, Erni D, Winslow RM, Intaglietta M. Resuscitation with polyethylene glycol-modified human hemoglobin improves microcirculatory blood flow and tissue oxygenation after hemorrhagic shock in awake hamsters. Crit Care Med. 2003 Jun;31(6):1824-30. doi: 10.1097/01.CCM.0000069340.16319.F2.
- Background Husain FA, Martin MJ, Mullenix PS, Steele SR, Elliott DC. Serum lactate and base deficit as predictors of mortality and morbidity. Am J Surg. 2003 May;185(5):485-91. doi: 10.1016/s0002-9610(03)00044-8.
- Background Regnier MA, Raux M, Le Manach Y, Asencio Y, Gaillard J, Devilliers C, Langeron O, Riou B. Prognostic significance of blood lactate and lactate clearance in trauma patients. Anesthesiology. 2012 Dec;117(6):1276-88. doi: 10.1097/ALN.0b013e318273349d.
- Background McNelis J, Marini CP, Jurkiewicz A, Szomstein S, Simms HH, Ritter G, Nathan IM. Prolonged lactate clearance is associated with increased mortality in the surgical intensive care unit. Am J Surg. 2001 Nov;182(5):481-5. doi: 10.1016/s0002-9610(01)00755-3.
- Background Abramson D, Scalea TM, Hitchcock R, Trooskin SZ, Henry SM, Greenspan J. Lactate clearance and survival following injury. J Trauma. 1993 Oct;35(4):584-8; discussion 588-9. doi: 10.1097/00005373-199310000-00014.
- Background Tsai AG, Cabrales P, Manjula BN, Acharya SA, Winslow RM, Intaglietta M. Dissociation of local nitric oxide concentration and vasoconstriction in the presence of cell-free hemoglobin oxygen carriers. Blood. 2006 Nov 15;108(10):3603-10. doi: 10.1182/blood-2006-02-005272. Epub 2006 Jul 20.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Subject | MP4OX | Protein / enzyme biologic | 500 ml | — |
| Subject | MP4OX | Protein / enzyme biologic | 750 ml | — |