Comparison of In-the-bag Stability Between Single-piece and Three-piece Intraocular Lens
Summary
Rapid advances of cataract surgery techniques and intraocular lens (IOL) technology have enabled the transition of cataract surgery from blindness relief to refractive correction. An ideal IOL is the critical component to achieve the refractive target of cataract surgery. Biocompatibility, rate of posterior capsule opacification (PCO) and visual quality have all been suggested as the critical factors of an ideal IOL and widely investigated. Recently, stability of IOL position has also been suggested as one of those critical factors due to its close correlation with postoperative visual function. Data suggests that IOL forward movement of 0.29 mm along the visual axis is associated with -0.4D myopic shift. Wang and colleagues recently reported that 0.5mm decentration of an aspheric IOL could eliminate its aberration-correcting effect. Poor stability could even lead to IOL exchange, an additional surgery that put both surgeons and patients in pain. As the supporting element of an IOL, the haptics are crucial to keep the IOL in place. Various haptic designs are being compared in terms of position stability of IOLs. Haptic designs of single-piece versus 3-piece are often compared because they are currently the most commonly used types. Single-piece IOLs have soft and broader haptics which are made of the same material as the optic, usually hydrophobic or hydrophilic acrylic, whereas 3-piece IOLs have rigid haptics which are made of poly methyl methacrylate (PMMA). Clinical studies comparing these haptic designs have yielded controversial results regarding their position stability in the capsular bag, which is the most recommended site for IOL fixation in an uneventful cataract surgery.
Timeline
- Start
- 2012-09
- Primary completion
- 2012-12
- Completion
- 2012-12
Publications
- Background Korynta J, Bok J, Cendelin J. Changes in refraction induced by change in intraocular lens position. J Refract Corneal Surg. 1994 Sep-Oct;10(5):556-64.
- Background Wang L, Koch DD. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch Ophthalmol. 2005 Sep;123(9):1226-30. doi: 10.1001/archopht.123.9.1226.
- Background Rosales P, Marcos S. Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements. J Opt Soc Am A Opt Image Sci Vis. 2006 Mar;23(3):509-20. doi: 10.1364/josaa.23.000509.
- Background de Castro A, Rosales P, Marcos S. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study. J Cataract Refract Surg. 2007 Mar;33(3):418-29. doi: 10.1016/j.jcrs.2006.10.054.
- Zhong X, Long E, Chen W, Xiang W, Liu Z, Chen H, Chen J, Lin Z, Lin H, Chen W. Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial. BMC Ophthalmol. 2016 Jul 8;16:100. doi: 10.1186/s12886-016-0283-4.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Background | Proparacaine | Other / unclassified | 0.5 % | Topical |
| Background | Subconjunctival dexamethasone | Unknown | 2 mg | Subcutaneous |