Two Low Volume Regimens for Colorectal Cancer Screening Colonoscopy
Summary
Colorectal cancer is the first neoplasm most commonly diagnosed in both sexes and the second leading cause of cancer death in Spain. Colorectal cancer screening Program in Barcelona was implanted in 2009 and approximately 1,500 colorectal cancer screening colonoscopies are performed annually at Hospital Clínic de Barcelona. Adequate colon preparation (anterograde cleansing with laxatives) improves polyp detection, decreases examination time, and complications. There are both low and high volume intestinal regimens with polyethylene glycol (PEG) as the main active ingredient or without it. Hypothesis: Two low volumen regimens, 1L PEG plus ascorbate and magnesium citrate plus picosulphate, at starting doses have the same Adenoma Detection Rate as cleansing solutions in preparation for screening colonoscopy.
Timeline
- Start
- 2020-03-11
- Primary completion
- 2022-06-28
- Completion
- 2022-06-28
Publications
- Background Hautefeuille G, Lapuelle J, Chaussade S, Ponchon T, Molard BR, Coulom P, Laugier R, Henri F, Cadiot G. Factors related to bowel cleansing failure before colonoscopy: Results of the PACOME study. United European Gastroenterol J. 2014 Feb;2(1):22-9. doi: 10.1177/2050640613518200.
- Background Schreiber S, Baumgart DC, Drenth JPH, Filip RS, Clayton LB, Hylands K, Repici A, Hassan C; DAYB Study Group. Colon cleansing efficacy and safety with 1 L NER1006 versus sodium picosulfate with magnesium citrate: a randomized phase 3 trial. Endoscopy. 2019 Jan;51(1):73-84. doi: 10.1055/a-0639-5070. Epub 2018 Jul 19.
- Background Bisschops R, Manning J, Clayton LB, Ng Kwet Shing R, Alvarez-Gonzalez M; MORA Study Group. Colon cleansing efficacy and safety with 1 L NER1006 versus 2 L polyethylene glycol + ascorbate: a randomized phase 3 trial. Endoscopy. 2019 Jan;51(1):60-72. doi: 10.1055/a-0638-8125. Epub 2018 Jul 19.
- Background DeMicco MP, Clayton LB, Pilot J, Epstein MS; NOCT Study Group. Novel 1 L polyethylene glycol-based bowel preparation NER1006 for overall and right-sided colon cleansing: a randomized controlled phase 3 trial versus trisulfate. Gastrointest Endosc. 2018 Mar;87(3):677-687.e3. doi: 10.1016/j.gie.2017.07.047. Epub 2017 Aug 10.
- Background Seo SI, Kang JG, Kim HS, Jang MK, Kim HY, Shin WG. Efficacy and tolerability of 2-L polyethylene glycol with ascorbic acid versus sodium picosulfate with magnesium citrate: a randomized controlled trial. Int J Colorectal Dis. 2018 May;33(5):541-548. doi: 10.1007/s00384-018-2989-7. Epub 2018 Mar 1.
- Background Lee SW, Bang CS, Park TY, Suk KT, Baik GH, Kim DJ. Split-dose Bowel Preparation for Colonoscopy: 2 Liters Polyethylene Glycol with Ascorbic Acid versus Sodium Picosulfate versus Oral Sodium Phosphate Tablets. Korean J Gastroenterol. 2017 Aug 25;70(2):89-95. doi: 10.4166/kjg.2017.70.2.89.
- Background Lai EJ, Calderwood AH, Doros G, Fix OK, Jacobson BC. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009 Mar;69(3 Pt 2):620-5. doi: 10.1016/j.gie.2008.05.057. Epub 2009 Jan 10.
- Background Patel M, Staggs E, Thomas CS, Lukens F, Wallace M, Almansa C. Development and validation of the Mayo Clinic Bowel Prep Tolerability Questionnaire. Dig Liver Dis. 2014 Sep;46(9):808-12. doi: 10.1016/j.dld.2014.05.020. Epub 2014 Jun 19.
- Background Guillaumes S, O'Callaghan CA. [Spanish adaptation of the free OxMaR software for minimization and randomization of clinical studies]. Gac Sanit. 2019 Jul-Aug;33(4):395-397. doi: 10.1016/j.gaceta.2018.07.013. Epub 2018 Nov 1. Spanish.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Subject | Plenvu | Unknown | — | — |