drugset / Trial / NCT04409587
Basal Insulin Glycemic ControL With DEglugec vs Aspart Via Pump
RandomizedCrossoverOpen-labelTreatment
Summary
The purpose of this investigator-initiated trial is to compare the effect of a daily injection of insulin degludec vs. basal insulin delivery via Continuous Subcutaneous Insulin Infusion (CSII), both in combination with bolus insulin delivery via the patient's usual insulin pump with insulin aspart, on glycemic variability, overall blood glucose control and incidence of hypoglycemia, all assessed by continuous glucose monitor (CGM), as well as patient satisfaction, in patients with type 1 diabetes currently using CSII.
Timeline
- Start
- 2018-04-12
- Primary completion
- 2020-05-16
- Completion
- 2020-11-01
Publications
- Results Misso ML, Egberts KJ, Page M, O'Connor D, Shaw J. Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochrane Database Syst Rev. 2010 Jan 20;2010(1):CD005103. doi: 10.1002/14651858.CD005103.pub2.
- Results Miller KM, Foster NC, Beck RW, Bergenstal RM, DuBose SN, DiMeglio LA, Maahs DM, Tamborlane WV; T1D Exchange Clinic Network. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care. 2015 Jun;38(6):971-8. doi: 10.2337/dc15-0078.
- Results Heise T, Hermanski L, Nosek L, Feldman A, Rasmussen S, Haahr H. Insulin degludec: four times lower pharmacodynamic variability than insulin glargine under steady-state conditions in type 1 diabetes. Diabetes Obes Metab. 2012 Sep;14(9):859-64. doi: 10.1111/j.1463-1326.2012.01627.x. Epub 2012 Jun 7.
- Results Lane W, Bailey TS, Gerety G, Gumprecht J, Philis-Tsimikas A, Hansen CT, Nielsen TSS, Warren M; Group Information; SWITCH 1. Effect of Insulin Degludec vs Insulin Glargine U100 on Hypoglycemia in Patients With Type 1 Diabetes: The SWITCH 1 Randomized Clinical Trial. JAMA. 2017 Jul 4;318(1):33-44. doi: 10.1001/jama.2017.7115.
- Results Bergenstal RM, Garg S, Weinzimer SA, Buckingham BA, Bode BW, Tamborlane WV, Kaufman FR. Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes. JAMA. 2016 Oct 4;316(13):1407-1408. doi: 10.1001/jama.2016.11708. No abstract available.
- Results Novo Nordisk. (2015). TRESIBA® (insulin degludec injection) Label. 28-29
- Results Novo Nordisk. (2000). NovoLog (insulin aspart [rDNA origin]) injection label. 21-22
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Comparator | Degludec | Protein / enzyme biologic | — | — |
| Comparator | insulin aspart | Protein / enzyme biologic | — | Subcutaneous |