drugset / Trial / NCT05980494

Lung Ultrasound Score and Inferior Vena Cava Diameter Compared to Pulse Pressure Variation

NCT05980494

Completed 150 enrolled Fayoum University Hospital
NaSingle-groupOpen-labelDiagnostic

Summary

Evaluation and management of intravascular volume are a central challenge for the critical ill patients. Hypotensive patients are commonly resuscitated with intravenous crystalloid fluid as a recommendation for treatment of many shock states. There has been a growing interest in the implementation of lung ultrasound in critical care management in the last decade as it is easy, bedside, non-expensive, non invasive and radiation free. The object of the current study is to assess the ability of lung and inferior vena cava sonography versus pulse pressure variation to predict fluid responsiveness in patients with circulatory failure on mechanical ventilation.

Timeline

Start
2022-09-13
Primary completion
2024-05-20
Completion
2024-06-20

Drugs

EvaluationDrugModalityDoseRoute
Subject sodium chloride Unknown 4 ml Intravenous