Trial of Low-intensity Anticoagulation to Reduce GI or Other Bleeding Complications With Equivalent Therapeutic Efficacy in HeartMate 3 LVAD Patients
Summary
The TARGET trial is a prospective, single-center, randomized, open-label, active-controlled inequality clinical trial designed to evaluate the safety and efficacy of low-intensity anticoagulation therapy (target INR 1.5-2.0) compared to standard anticoagulation therapy (target INR 2.0-3.0) in patients receiving a HeartMate 3 Left Ventricular Assist Device (LVAD). Despite the demonstrated effectiveness of HeartMate 3 LVAD in reducing thromboembolic complications, standard anticoagulation treatment guidelines recommend maintaining an INR between 2.0 and 3.0, which can lead to a substantial risk of bleeding, especially gastrointestinal (GI) bleeding. Preliminary studies, such as MAGENTUM 1, have indicated potential safety and reduced bleeding events at lower INR targets (1.5-1.9). However, robust evidence through randomized controlled trials is still required. The primary objective of the TARGET trial is to determine if low-intensity anticoagulation therapy significantly reduces the incidence of major bleeding and thrombotic events compared to standard therapy within 6 months post-randomization. Secondary objectives include evaluating the safety and hematological complications associated with low-intensity anticoagulation. The study will enroll adult patients aged ≥19 years who have been stably maintained on standard INR therapy (2.0-3.0) for at least 30 days post-HeartMate 3 LVAD implantation. Participants will be randomized in a 1:1 ratio into two groups: the low-intensity INR group (target INR 1.5-2.0) and the standard INR group (target INR 2.0-3.0). Randomization will be stratified based on the presence of atrial fibrillation. The primary endpoint is a composite of hemocompatibility-related events, including major bleeding, stroke, and pump thrombosis, occurring within 6 months after randomization, as defined by INTERMACS criteria. Secondary endpoints encompass clinical outcomes such as all-cause mortality, cardiac death, LVAD-related thromboembolic events, stroke, systemic embolism, myocardial infarction, major bleeding incidents, and the rate and number of LVAD-related hospital readmissions and reoperations. Additionally, INR management outcomes, including time in therapeutic range (TTR) and frequency of warfarin dose adjustments, will be assessed. The trial duration is approximately 36 months, including a 24-month enrollment period, a 6-month follow-up period for each participant, and time allocated for data analysis and reporting. Safety will be rigorously monitored by a Data Safety Monitoring Board (DSMB) and Clinical Events Committee (CEC), ensuring participant safety and data integrity throughout the study. This trial aims to provide critical insights that could optimize anticoagulation strategies in LVAD patients, potentially improving patient safety by reducing bleeding risks without compromising thrombotic event protection.
Timeline
- Start
- 2025-10
- Primary completion
- 2028-10
- Completion
- 2029-01
Publications
- Results Netuka I, Ivak P, Tucanova Z, Gregor S, Szarszoi O, Sood P, Crandall D, Rimsans J, Connors JM, Mehra MR. Evaluation of low-intensity anti-coagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study. J Heart Lung Transplant. 2018 May;37(5):579-586. doi: 10.1016/j.healun.2018.03.002. Epub 2018 Apr 11.
- Results Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, Boyce SW, Najjar SS, Jeevanandam V, Anderson AS, Gregoric ID, Mallidi H, Leadley K, Aaronson KD, Frazier OH, Milano CA. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med. 2017 Feb 2;376(5):451-460. doi: 10.1056/NEJMoa1602954.
- Results Desai SR, Hwang NC. 2023 ISHLT Guidelines for Mechanical Circulatory Support. J Cardiothorac Vasc Anesth. 2023 Dec;37(12):2419-2422. doi: 10.1053/j.jvca.2023.07.044. Epub 2023 Aug 8. No abstract available.
- Results Mehra MR, Naka Y, Uriel N, Goldstein DJ, Cleveland JC Jr, Colombo PC, Walsh MN, Milano CA, Patel CB, Jorde UP, Pagani FD, Aaronson KD, Dean DA, McCants K, Itoh A, Ewald GA, Horstmanshof D, Long JW, Salerno C; MOMENTUM 3 Investigators. A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. N Engl J Med. 2017 Feb 2;376(5):440-450. doi: 10.1056/NEJMoa1610426. Epub 2016 Nov 16.
- Results Mehra MR, Goldstein DJ, Uriel N, Cleveland JC Jr, Yuzefpolskaya M, Salerno C, Walsh MN, Milano CA, Patel CB, Ewald GA, Itoh A, Dean D, Krishnamoorthy A, Cotts WG, Tatooles AJ, Jorde UP, Bruckner BA, Estep JD, Jeevanandam V, Sayer G, Horstmanshof D, Long JW, Gulati S, Skipper ER, O'Connell JB, Heatley G, Sood P, Naka Y; MOMENTUM 3 Investigators. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. N Engl J Med. 2018 Apr 12;378(15):1386-1395. doi: 10.1056/NEJMoa1800866. Epub 2018 Mar 11.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Subject | Warfarin | Small molecule | — | — |