The Effect of Neuraxial Analgesia on Maternal Breastfeeding
Summary
A previous randomized trial showed a possible negative association with labor neuraxial analgesia with high compared to low doses of fentanyl, and breastfeeding at 6 weeks postpartum. The significance of this study would be to validate or refute these findings. In addition, we hope to better evaluate the impact of cumulative dose of fentanyl on breastfeeding success in the initial postpartum period as well as at 6 weeks and 6 months post delivery. In order to better assess the quality of breastfeeding, we will utilize a validated breastfeeding assessment tool, LATCH (Latch, Audible swallowing, Type of Nipple, Comfort, and Help). This validated tool can assess maternal and infant variables, define areas of needed intervention, and determine priorities in providing patient teaching. The LATCH assessment has been shown to be a predictor of breastfeeding duration. We also plan to vary the dosage of fentanyl analgesia to determine the relationship between doses below 150 micrograms and changes in breastfeeding assessments. If a clear association between decreased breastfeeding and total fentanyl is identified, then regimens to reduce cumulative doses of fentanyl can be developed to improve the likelihood of breastfeeding success in mothers that desire to breastfeed. Prior observational studies have inferred epidurals negatively affect breastfeeding by decreasing maternal plasma oxytocin release which may adversely affect infant neurobehavioral development. In a study by Beilin et al., it was reported that mothers receiving a high cumulative dose (\> 150 microgram) epidural fentanyl were more likely to have stopped nursing 6 weeks postpartum compared with groups receiving no fentanyl or those receiving \< 150 microgram. The study however, was underpowered to detect differences in breastfeeding prior to hospital discharge. In addition, the breastfeeding assessment tool utilized resulted in binary assessments, and therefore, a global rating of the quality of breastfeeding was not available.
Timeline
- Start
- 2010-01
- Primary completion
- 2016-12
- Completion
- 2016-12
Publications
- Background Baumgarder DJ, Muehl P, Fischer M, Pribbenow B. Effect of labor epidural anesthesia on breast-feeding of healthy full-term newborns delivered vaginally. J Am Board Fam Pract. 2003 Jan-Feb;16(1):7-13. doi: 10.3122/jabfm.16.1.7.
- Background Riordan J, Gross A, Angeron J, Krumwiede B, Melin J. The effect of labor pain relief medication on neonatal suckling and breastfeeding duration. J Hum Lact. 2000 Feb;16(1):7-12. doi: 10.1177/089033440001600103.
- Background Rahm VA, Hallgren A, Hogberg H, Hurtig I, Odlind V. Plasma oxytocin levels in women during labor with or without epidural analgesia: a prospective study. Acta Obstet Gynecol Scand. 2002 Nov;81(11):1033-9. doi: 10.1034/j.1600-0412.2002.811107.x.
- Background Beilin Y, Bodian CA, Weiser J, Hossain S, Arnold I, Feierman DE, Martin G, Holzman I. Effect of labor epidural analgesia with and without fentanyl on infant breast-feeding: a prospective, randomized, double-blind study. Anesthesiology. 2005 Dec;103(6):1211-7. doi: 10.1097/00000542-200512000-00016.
- Background Jensen D, Wallace S, Kelsay P. LATCH: a breastfeeding charting system and documentation tool. J Obstet Gynecol Neonatal Nurs. 1994 Jan;23(1):27-32. doi: 10.1111/j.1552-6909.1994.tb01847.x.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Comparator | Bupivacaine | Other / unclassified | 0.625 mg/ml | Other |
| Comparator | Bupivacaine | Other / unclassified | 0.8 mg/ml | Other |
| Comparator | Bupivacaine | Other / unclassified | 1 mg/ml | Other |
| Comparator | Bupivacaine | Other / unclassified | 1.25 mg/ml | Other |
| Comparator | Bupivacaine | Other / unclassified | 2.5 mg | Other |
| Comparator | Fentanyl | Other / unclassified | 1 ug/ml | Other |
| Comparator | Fentanyl | Other / unclassified | 2 ug/ml | Other |
| Comparator | Fentanyl | Other / unclassified | 15 ug | Other |
Indications
No indication recorded.