drugset / Trial / NCT01199276

Hip Fracture Surgery in Elderly Patients

NCT01199276 ↗

Phase 2 Completed 256 enrolled Air Liquide OptumInsight · collab
RandomizedParallel-groupDouble-blindTreatment

Summary

The objective of this study is to evaluate the incidence of Post-Operative Delirium (POD), diagnosed with the Confusion Assessment Method (CAM), in elderly patients undergoing hip fracture surgery under general anaesthesia with xenon or sevoflurane, for a period of four days post-surgery.

Timeline

Start
2010-09
Primary completion
2014-10
Completion
2014-10

Outcome

Missed primary endpoint

paper The incidence of delirium with xenon (9.7% [95% CI: 4.5 -14.9]) or with sevoflurane (13.6% [95% CI: 7.8 -19.5]) were not significantly different (P=0.33). PMID 29397119 ↗

Drugs

EvaluationDrugModalityDoseRoute
Comparator Sevoflurane Other / unclassified — —
Subject Xenon Other / unclassified 60 % —

Indications