drugset / Trial / NCT03620942
Development of Advanced Double Intravenous Vasopressor Automated (ADIVA) System
RandomizedParallel-groupDouble-blindTreatment
Summary
Maternal hypotension during spinal anaesthesia for Caesarean delivery may bring various adverse effects. It is therefore important to closely monitor hypotension during spinal anaesthesia, however current technology does not allow the blood pressure monitoring to respond in timely manner should there be any occurrence of hypotension. The investigators developed an advanced double-intravenous vasopressor automated system (ADIVA) so as to tackle this issue via novel algorithm to control blood pressure more rigorously with more stable haemodynamic profiles.
Timeline
- Start
- 2018-11-07
- Primary completion
- 2025-12-31
- Completion
- 2026-12-31
Publications
- Tan HS, Nagarajan S, Chan JJI, Tan CW, Sultana R, Sia ATH, Sng BL. Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial. BMC Anesthesiol. 2023 Jan 26;23(1):33. doi: 10.1186/s12871-023-01992-7.
- Nagarajan S, Chan JJI, Tan CW, Al-Hashim ZGA, Sultana R, Sia ATH, Sng BL. An advanced double intravenous vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: A pilot study. Eur J Anaesthesiol. 2022 Jan 1;39(1):42-49. doi: 10.1097/EJA.0000000000001496.
Drugs
| Evaluation | Drug | Modality | Dose | Route |
|---|---|---|---|---|
| Subject | Ephedrine | Small molecule | 2 mg | Intravenous |
| Subject | Ephedrine | Small molecule | 4 mg | Intravenous |
| Subject | Ephedrine | Small molecule | 6 mg | Intravenous |
| Subject | Phenylephrine | Small molecule | 25 ug | Intravenous |
| Subject | Phenylephrine | Small molecule | 50 ug | Intravenous |
| Subject | Phenylephrine | Small molecule | 75 ug | Intravenous |